| Single-phase commercial equipment | 100–120 V AC or 220–240 V AC | 1–16 A | 50 or 60 Hz | Two-line EMI filter with common-mode choke, X capacitor, and Y capacitors | −25°C to +85°C | Indoor equipment, pollution degree 2, non-condensing humidity; provide protective earth where required | Confirm rated voltage, continuous RMS current, leakage current, terminal arrangement, and safety approvals for the destination market |
| Three-phase industrial machinery | 380–415 V AC or 440–480 V AC line-to-line | 10–100 A | 50 or 60 Hz | Three-phase, three-line or four-line filter; use a neutral conductor only when required by the system | −25°C to +70°C | Industrial cabinet, vibration, dust, and elevated ambient temperature; maintain short, low-impedance protective-earth connections | Check phase configuration, prospective short-circuit current, overload capability, heat dissipation, and enclosure rating |
| Variable-frequency drive or motor controller | 200–240 V AC or 380–480 V AC | 5–60 A | 50 or 60 Hz input; high-frequency switching noise at the output | Input EMC filter; use a motor-output filter only when the drive and motor-cable installation require it | −10°C to +50°C without derating in many installations | Use shielded cables, 360-degree shield termination where applicable, and separation between power and control wiring | Verify compatibility with switching frequency, motor-cable length, leakage-current limits, and drive manufacturer requirements |
| Switch-mode power supply input | 90–264 V AC universal input | 0.5–5 A | 47–63 Hz | Compact single-phase EMI filter designed for differential-mode and common-mode noise | −25°C to +85°C | Suitable for enclosed electronic equipment; consider airflow, inrush current, and capacitor aging at high temperature | Ensure the filter current rating exceeds maximum input current, including startup conditions and low-line operation |
| Low-voltage DC control equipment | 12 V, 24 V, 36 V, or 48 V DC | 1–30 A | DC; switching noise commonly ranges from tens of kHz to several MHz | DC feed-through filter or common-mode choke with appropriate differential-mode capacitance | −40°C to +85°C | Automotive, telecom, or control-panel environments may require vibration, reverse-polarity, and transient protection | Do not use AC-rated capacitors without confirming DC suitability; check polarity, ripple current, voltage derating, and grounding method |
| Medical electrical equipment | 100–240 V AC, depending on the intended market | 1–10 A | 50 or 60 Hz | Medical-grade filter with controlled leakage current and suitable insulation system | 0°C to +40°C is common for equipment used in controlled indoor areas | Patient-connected applications require particular attention to leakage current, creepage, clearance, and protective-earth integrity | Select against the applicable medical-equipment standard and verify normal, single-fault, dielectric-strength, and leakage-current performance |
| Outdoor or harsh-environment equipment | 120 V AC, 230 V AC, or 400–480 V AC | 2–40 A | 50 or 60 Hz | Sealed or coated filter assembly with surge protection selected separately or integrated where appropriate | −40°C to +85°C, subject to component and enclosure limits | Consider condensation, salt mist, UV exposure, dust, water ingress, altitude, vibration, and corrosion-resistant terminals | Check enclosure protection level, climate category, surge environment, creepage distance, and current derating at high ambient temperature |